How to deflate a vertical radiator: detailed steps and analysis of frequently asked questions
With the advent of winter, the frequency of use of radiators gradually increases, and radiator deflation is a key step to ensure heating effect. Many users report that the radiator is not hot or is not hot locally, which is often caused by air accumulation inside. This article will introduce in detail how to deflate a vertical radiator, along with relevant data and FAQs.
1. The necessity of deflating vertical radiators

During use of the radiator, air may accumulate inside, resulting in poor hot water circulation and affecting the heating effect. Deflating can remove the air and restore the radiator to its normal working condition.
| Problem phenomenon | Possible reasons | Solution |
|---|---|---|
| The radiator is not hot locally | Internal gas accumulation | Deflate |
| The radiator is not hot overall | The water supply temperature is insufficient or the valve is closed | Check water supply system |
| There is a sound of water flowing from the radiator | Internal air is not exhausted | Deflate repeatedly |
2. Specific steps for deflating vertical radiators
The following is the detailed operation process for deflating the vertical radiator:
| steps | Operating Instructions | Things to note |
|---|---|---|
| 1. Turn off the heating system | Make sure the radiator is cool to avoid burns | Wait 10-15 minutes |
| 2. Find the bleed valve | Usually on the top of the radiator, there is a small screw or valve | Use a screwdriver or special key |
| 3. Prepare water receiving tools | Place a towel or container under the release valve | Prevent water from flowing to the ground |
| 4. Slowly unscrew the air release valve | Turn counterclockwise and when you hear a "hissing" sound, the air is discharged. | Do not unscrew the valve completely |
| 5. Wait for the water flow to stabilize | When the water flow continues without bubbles, close the valve | Tighten clockwise |
| 6. Check the radiator | Restart the heating system and observe whether it returns to normal | Repeat deflation if necessary |
3. Frequently Asked Questions and Answers
The following are common questions users have about vertical radiators deflating:
| question | Answer |
|---|---|
| What should I do if the air release valve cannot be tightened? | Use lubricating oil or ask professionals to handle it and avoid violent operations. |
| Is the radiator still not hot after deflating? | Check whether the water supply pipe is blocked or the valve is fully open |
| How often does it need to be deflated? | Usually 1-2 times a heating season, depending on the specific situation |
| What should I do if the water flow does not stop when deflating? | Close the valve immediately and check whether the valve is damaged |
4. Precautions
1.Safety first: To avoid burns when deflating, make sure the radiator is cool before operating.
2.Tool preparation: Use appropriate tools such as screwdrivers or special bleeder keys.
3.Avoid excessive deflation: Excessive deflation time may cause the system pressure to drop and affect the heating effect.
4.Professional help: If the problem cannot be solved, it is recommended to contact professional maintenance personnel.
5. Summary
Bleeding a vertical radiator is an effective way to solve heating problems. It's easy to do but requires attention to detail. Through the steps and table data in this article, users can easily complete the deflation operation to ensure the heating effect in winter. If you still have questions, it is recommended to consult a professional.
check the details