How to calibrate a forehead thermometer
With the improvement of health awareness, forehead thermometers are widely used as daily temperature measurement tools. However, after a period of use, a forehead thermometer may develop measurement deviations, so regular calibration is essential. This article will introduce the calibration method of the forehead thermometer in detail, and attach relevant data for reference.
1. The necessity of calibration of forehead thermometer

The forehead thermometer measures human body temperature through an infrared sensor. Long-term use or environmental changes may cause the sensor accuracy to decrease. Calibration can ensure accurate measurement results, which is especially important in medical and public places.
2. Preparations before calibration
1.Check device status: Confirm that the forehead thermometer has sufficient power and the sensor is not damaged.
2.Prepare reference temperature source: Such as a blackbody furnace or a standard mercury thermometer.
3.stable environment: The ambient temperature should be maintained at 20-25°C during calibration.
| Calibration tools | Applicable scenarios | Accuracy requirements |
|---|---|---|
| Blackbody furnace | Professional organization calibration | ±0.1℃ |
| Standard mercury thermometer | Easy calibration at home | ±0.2℃ |
3. Detailed explanation of calibration steps
Method 1: Use blackbody furnace calibration (professional recommendation)
1. Set the blackbody furnace to 35.0°C (simulating human body temperature).
2. Aim the forehead thermometer at the center of the blackbody furnace at a distance of 3-5cm.
3. Record the measured value. If the deviation exceeds ±0.3°C, it needs to be adjusted according to the instructions.
Method 2: Water bath method calibration (applicable to families)
1. Put the mercury thermometer and warm water (about 36℃) into the thermos cup.
2. After waiting for the temperature to stabilize, use a forehead thermometer to measure the water surface.
3. Compare the two readings. If the deviation is large, calibration is required.
| Calibration method | Operation difficulty | Calibration period |
|---|---|---|
| Blackbody furnace calibration | high | 1 time per year |
| Water bath calibration | low | Once every 3 months |
4. Frequently Asked Questions and Solutions
Q1: Still not accurate after calibration?
Possible reasons: sensor aging or ambient temperature fluctuations. It is recommended to replace the equipment or contact the manufacturer.
Q2: How to quickly verify without professional tools?
Measure the body temperature of multiple people (in a healthy state). If the results deviate from the range of 36.5-37.2℃, calibration is required.
5. Maintenance tips
1. Avoid direct sunlight or storage in high temperature and humid environment.
2. Clean the sensor window regularly (wipe lightly with alcohol cotton).
3. Remove the battery when not in use for a long time.
Summary
Forehead thermometer calibration is a key step to ensure accurate measurement. Users can choose professional or home calibration methods according to actual conditions, and maintain the equipment regularly. Through the structured data and operation guidance provided in this article, we hope to help you complete calibration easily.
check the details
check the details